show spantree vlanlist

Enterasys D-Series CLI Reference

8-15

D2(su)->clear spantree mstmap 2

show spantree vlanlist

Use this command to display the Spanning Tree ID(s) assigned to one or more VLANs.

Syntax

show spantree vlanlist [vlan-list]

Parameters

Defaults

If not specified, SID assignment will be displayed for all VLANs.

Mode

Switch command, read‐only.

Example

This example shows how to display the SIDs mapped to VLAN 1. In this case, SIDs 2, 16 and 42 
are mapped to VLAN 1. For this information to display, the SID instance must be created using the 
set spantree msti command as described in “

set spantree msti

” on page 8‐12, and the FIDs must 

be mapped to SID 1 using the set spantree mstmap command as described in 

set spantree 

mstmap

” on page 8‐14:

D2(su)->show spantree vlanlist 1

The following SIDS are assigned to VLAN 1: 2 16 42

show spantree mstcfgid

Use this command to display the MST configuration identifier elements, including format selector, 
configuration name, revision level, and configuration digest.

Syntax

show spantree mstcfgid

Parameters

None.

Defaults

None.

Mode

Switch command, read‐only.

Example

This example shows how to display the MST configuration identifier elements. In this case, the 
default revision level of 0, and the default configuration name (a string representing the bridge 

vlan‐list

(Optional) Displays SIDs assigned to specific VLAN(s).