clear rmon capture
15-24
RMON Configuration
Mode
Switch command, read‐write.
Example
This example shows how to create RMON capture entry 1 to “listen” on channel 628:
D2(rw)->set rmon capture 1 628
clear rmon capture
Use this command to clears an RMON capture entry.
Syntax
clear rmon capture index
Parameters
Defaults
None.
Mode
Switch command, read‐write.
Example
This example shows how to clear RMON capture entry 1:
D2(rw)->clear rmon capture 1
index
Specifies the capture entry to be cleared.
See also other documents in the category Enterasys Networks Computer Accessories:
- Enterasys RoamAbout RBT-1002-EU (28 pages)
- BL-89710ENT (28 pages)
- Enterasys Gold Distributed Forwarding Engine 4G4205-72 (100 pages)
- VH-8G-L3 (41 pages)
- 2H252-25R (64 pages)
- 6H302-48 (58 pages)
- ENTERASYS ATX (82 pages)
- CSX7000 (729 pages)
- Enterasys Matrix 9033989-06 (90 pages)
- Enterasys D2 D2G124-12 (496 pages)
- Enterasys Matrix 6H352-25 (56 pages)
- 5G1XX (144 pages)
- 2S4082-25-SYS (108 pages)
- 2200 (330 pages)
- Enterasys Gold Distributed Forwarding Engine 4H4202-72 (90 pages)
- 6000 (231 pages)
- 6E2xx (430 pages)
- Enterasys Matrix DFE-Gold Series (90 pages)
- Enterasys Vertical Horizon VH-2402S2 (7 pages)
- VH-2402S (58 pages)
- Enterasys SecureStack B2 B2G124-24 (80 pages)
- 24-Port (26 pages)
- Enterasys Matrix C1H124-48 (64 pages)
- 2G4072-52 (70 pages)
- Enterasys Diamond Distributed Forwarding Engine 7KR4297-02 (64 pages)
- 2000 (188 pages)
- Enterasys Vertical Horizon VH-8G (48 pages)
- V2H124-24P (68 pages)
- Enterasys Platinum Distributed Forwarding Engine 7G4205-72 (96 pages)
- Enterasys SecureStack A2 A2H124-48P (82 pages)
- VH-4802 (56 pages)
- A2H124-24FX (82 pages)
- 700 (182 pages)
- C2K122-24 (70 pages)