set macauthentication portinitialize

17-26

Security Configuration

Usage

Enabling port(s) for MAC authentication requires globally enabling MAC authentication on the 
switch as described in 

set macauthentication

” on page 17‐24, and then enabling it on a port‐by‐

port basis. By default, MAC authentication is globally disabled and disabled on all ports.

Example

This example shows how to enable MAC authentication on 

ge

.2.1 though 5:

D2(su)->set macauthentication port enable ge.2.1-5

set macauthentication portinitialize

Use this command to force one or more MAC authentication ports to re‐initialize and remove any 
currently active sessions on those ports.

Syntax

set macauthentication portinitialize port-string

Parameters

Defaults

None.

Mode

Switch command, read‐write.

Example

This example shows how to force 

ge

.2.1 through 5 to initialize:

D2(su)->set macauthentication portinitialize ge.2.1-5

set macauthentication portquietperiod

This sets the number of seconds following a failed authentication before another attempt may be 
made on the port.

Syntax

set macauthentication portquietperiod time port-string

Parameters

port‐string

Specifies the MAC authentication port(s) to re‐initialize. For a detailed 
description of possible port‐string values, refer to “

Port String Syntax Used 

in the CLI

” on page 6‐1. 

time

Period in seconds to wait after a failed authentication. By default, this is 30 
seconds.

port‐string

Specifies the ports for which the quit period is to be applied. For a detailed 
description of possible port‐string values, refer to “

Port String Syntax Used 

in the CLI