Set maclock static, Clear maclock static, Set maclock static -57 clear maclock static -57 – Enterasys Networks D-Series User Manual
Page 519
set maclock static
Enterasys D-Series CLI Reference
17-57
Example
This example shows how to remove a MAC from the list of static MACs allowed to communicate
on port
ge
.3.2:
D2(rw)->clear maclock 0e-03-ef-d8-44-55 ge.3.2
set maclock static
Use this command to set the maximum number of static MAC addresses allowed per port. Static
MACs are administratively defined.
Syntax
set maclock static port-string value
Parameters
Defaults
None.
Mode
Switch command, read‐write.
Example
This example shows how to set the maximum number of allowable static MACs to 2 on
ge
.3.1:
D2(rw)->set maclock static ge.3.1 2
clear maclock static
Use this command to reset the number of static MAC addresses allowed per port to the default
value of 20.
Syntax
clear maclock static port-string
Parameters
Defaults
None.
port‐string
Specifies the port on which to set the maximum number of static MACs
allowed. For a detailed description of possible port‐string values, refer to
“
Port String Syntax Used in the CLI
value
Specifies the maximum number of static MAC addresses allowed per
port. Valid values are 0 to 20.
port‐string
Specifies the port on which to reset number of static MAC addresses
allowed. For a detailed description of possible port‐string values, refer to
“