set summertime recurring

Enterasys D-Series CLI Reference

2-19

Defaults

If an offset is not specified, none will be applied.

Mode

Switch command, read‐write.

Example

This example shows how to set a daylight savings time start date of April 4, 2004 at 2 a.m. and an 
ending date of October 31, 2004 at 2 a.m. with an offset time of one hour:

D2(su)->set summertime date April 4 2004 02:00 October 31 2004 02:00 60

set summertime recurring

Use this command to configure recurring daylight savings time settings. These settings will start 
and stop daylight savings time at the specified day of the month and hour each year and will not 
have to be reset annually.

Syntax

set summertime recurring start_week start_day start_month start_hr_min end_week

end_day end_month end_hr_min [offset_minutes]

Parameters

start_year 

Specifies the year to start daylight savings time.

start_hr_min

Specifies the time of day to start daylight savings time. Format is hh:mm.

end_month

Specifies the month of the year to end daylight savings time.

end_date

Specifies the day of the month to end daylight savings time. 

end_year

Specifies the year to end daylight savings time.

end_hr_min

Specifies the time of day to end daylight savings time. Format is hh:mm.

offset_minutes

(Optional) Specifies the amount of time in minutes to offset daylight 
savings time from the non‐daylight savings time system setting. Valid 
values are 1 ‐ 1440.

start_week 

Specifies the week of the month to restart daylight savings time. Valid 
values are: first, second, third, fourth, and last.

start_day 

Specifies the day of the week to restart daylight savings time. 

start_hr_min

Specifies the time of day to restart daylight savings time. Format is 
hh:mm.

end_week

Specifies the week of the month to end daylight savings time. 

end_day

Specifies the day of the week to end daylight savings time.

end_hr_min

Specifies the time of day to end daylight savings time. Format is hh:mm.

offset_minutes

(Optional) Specifies the amount of time in minutes to offset daylight 
savings time from the non‐daylight savings time system setting. Valid 
values are 1 ‐ 1440.