Alarm Group Commands

Enterasys D-Series CLI Reference

15-9

Alarm Group Commands

Purpose

To display, configure, and clear RMON alarm entries and properties.

Commands

show rmon alarm

Use this command to display RMON alarm entries. The RMON alarm group periodically takes 
statistical samples from RMON variables and compares them with previously configured 
thresholds. If the monitored variable crosses a threshold an RMON event is generated.

Syntax

show rmon alarm [index]

Parameters

Defaults

If index is not specified, information about all RMON alarm entries will be displayed.

Mode

Switch command, read‐only.

Example

This example shows how to display RMON alarm entry 3:

D2(rw)->show rmon alarm 3

Index 3

---------------------

Owner = Manager

Status = valid

Variable = 1.3.6.1.4.1.5624.1.2.29.1.2.1.0

Sample Type = delta Startup Alarm = rising

Interval = 30 Value = 0

Rising Threshold = 1 Falling Threshold = 0

Rising Event Index = 2 Falling Event Index = 0

Table 15‐40

 provides an explanation of the command output.

For information about...

Refer to page...

show rmon alarm

15-9

set rmon alarm properties

15-10

set rmon alarm status

15-11

clear rmon alarm

15-12

index

(Optional) Displays RMON alarm entries for a specific entry index ID.