Definitions tab page – Yaskawa MP900 Series Machine Controller for Standard Operation User Manual
Page 88

2.3 List and Print Managers
2-55
2
c) Detailed Settings for O Registers
Enter in hexadecimal the leading and ending numbers of the O registers to be printed
in the O Register List Details Window.
The method for selecting the register range is the same as for S registers. Refer to
Detailed Settings for S Registers for details.
d) Detailed Settings for M Registers
Enter in hexadecimal the leading and ending numbers of the M registers to be printed
in the M Register List Details Window.
The method for selecting the register range is the same as for S registers. Refer to
Detailed Settings for S Registers for details.
e) Detailed Settings for D Registers
Designate Select All or Individual Select in the D Register List Details Window.
f) Detailed Settings for # Registers
Designate Select All or Individual Select in the # Register List Details Window.
Definitions Tab Page
System definition, scan time, module configuration definition, failure monitor definition,
and data trace printing data can be selected.
Button
Details
Map List
Prints the M register utilization status list before the M registers.
Check Item
Details
Map List
Prints the D register utilization status list before the D registers.
Select All
Prints all drawing and function program D registers.
Individual Select
Selects drawing or function programs, and prints the D registers
used in the selected programs.
Check Item
Details
Print Cross
Prints the # register cross-reference information before the # reg-
isters.
Print Data
Prints the # register data.
Select All
Selects and prints all drawing and function program # registers.
Individual Select
Selects drawing or function programs, and prints the # registers
used in the selected programs.