Monitoring Tools
6.3.3 Stopping and Restarting the Monitoring Display
6-8
6
Commands Displayed for Monitoring
The following table shows the commands that are displayed in reversed color in the monitor
mode.
6.3.3 Stopping and Restarting the Monitoring Display
This section explains how to stop and restart the monitoring display.
Stopping the Monitoring Display
To stop the monitoring display, press the Space Key while the focus is on the Motion Editor
Window. The cursor condition will be changed from reversed color display to edit. The pro-
gram can be edited while the monitoring display is stopped.
If an attempt is made to edit and save a program that is being executed while the monitoring display is
stopped, the program will not run normally.
Restarting the Monitoring Display
The following procedure can be used to restart a monitoring display that has been stopped.
Command
Command
MOV
Positioning
MVS
Linear interpolation
MCW
Clockwise circular interpola-
tion
SPH
Spherical interpolation
MCC
Helical circular interpolation
ZRN
Zero point return
SKP
Skip
MVT
Set time positioning
SPL
Spline path compensation
EXM
External positioning
PFN
In-position check
UFC
User function call
ACC
Acceleration time change
DCC
Deceleration time change
SCC
S-curve time constant change
TIM
Dwell time
IOW
I/O wait
MSEE
Subroutine call
00003
00004
00005
VEL
ACC
MOV
[A1] 3000;
[A1] 2000;
[A1] 1000;
00003
00004
00005
VEL
ACC
MOV
[A1] 3000;
[A1] 2000;
[A1] 1000;
Editing cursor