Module Configuration Definitions
3.5.9 218IF Transmission Definitions
3-52
3
The 218IF Transmission Definitions Window Menus
The following table shows the menu displayed in the 218IF Transmission Definitions Win-
dow.
Setting 218IF Transmission Definitions
The CP-218 Transmission Definitions Window is composed of two tab pages: The Trans-
mission Parameters and Status Tabs.
Setting 218IF Transmission Parameters
The 218IF Transmission Definitions Window contains the various parameters required to
use the 218IF transmission system.
Parameter Settings Tab Page
Set the transmission parameters and connection parameters in the Transmission Parameters
Tab.
Menu Command
Function
Edit (E)
My Port: TCP/IP
Setting (M)
Sets local station and TCP/IP.
Ethernet Address
Setting (A)
Sets the Ethernet address of the remote station.
Transmission
Parameters Default
Setting (D)
Sets transmission parameters to default value.
Assignment Delete (C)
Deletes assignment data.
Tab Name
Function
Transmission Parameters
Sets the 218IF transmission parameters.
Status
Displays the transmission status.
Setting Item
Details
IP Address
Input the local station's IP address. Do not used the same address as
another node in the Ethernet system.
Response Time
Input the time (0 to 255) that the CP-218 will wait for a response
after sending a command using the system function (the MSG-SND
function). If a response is not received and a timeout occurs, the
transmission will be retried. (The number of retries is set with the
Count of Retry.)
Input 0 for the Response Time if the Count of Retry is set to 0 and
the Protocol Type is set to MEMOBUS.