beautypg.com

4 function windows – Yaskawa MP900 Series Machine Controller for Standard Operation User Manual

Page 77

background image

Manager Functions

2.2.4 Function Windows

2-44

2

∗ 1.

Motion Parameters (M) is only displayed when the MP930 is used.

∗ 2.

Position Monitor (P), Task Monitor (T), and Motion Alarm (A) are

active only when online.

2.2.4 Function Windows

More than one function window can be open at the same time in the Engineering Manager.
The menus differ for each function window. The menu for the active function window will
be displayed. Refer to the explanations for each function window menu.

In the following diagram, the Motion Editor and Scan Time Windows are open. The Engi-
neering Manager uses the Motion Editor Menu because the Motion Editor is the active func-
tion window. The menu will switch to the Scan Time Menu if the Scan Time Window is
made active.

Tool (T)

Register List (C)

Calls programming support tools.

Cross Reference (X)

Disable Coil List (D)

Comment List (C)

Register Replace (S)

C Register (C)

C Register Map (M)

Displays C registers.

Data Table Definition (G)

Table Data Map (L)

Displays table data.

Motion Program (M)

Motion Editor (E)

Calls motion programming tools.

Position Monitor (P)

*2

Task Monitor (T)

*2

Motion Alarm (A)

*2

Print (P)

Prints data.

Exit (X)

Closes the Engineering Manager.

View (V)

Tool Bar (T)

Displays and hides the Tool Bar.

Status Bar (S)

Displays and hides the Status Bar.

Help (H)

About Application (A)

Displays version information for the CP-717.

Help Topics (H)

Searches for topics.

Menu Command