3.6 MP930 Module Definitions

3-125

3

The ending register number of "020F" is set considering the MECHATROLINK devices that are likely
to be connected. Reset this value if more registers are needed.

4. Deleting Allocation Data

a) To delete a station's allocation data, move the cursor to the row of the station to be

deleted, select Edit (E), and then Assignment Delete (A).

b) The station's allocation data will be deleted.

I/O Map Tab Page

This tab page displays the status of the Machine Controller's I/O allocations. In the MP930,
the I/O allocation data set in the I/O Assignment Tab Page will be displayed but cannot be
changed.

Table 3.19 I/O Map Tab Page

Status Tab Page

This tab page can be used to check the MECHATROLINK's transmission status.

The tab page only displays the present status of transmissions; the status cannot be changed.

HI

Allocates to an input set for a high-speed scan.

HO

Allocates to an output set for a high-speed scan.

LI

Allocates to an input set for a low-speed scan.

LO

Allocates to an output set for a low-speed scan.

DEL

Deletes allocation.

INFO