Setting local i/o definitions – Yaskawa MP900 Series Machine Controller for Standard Operation User Manual

Page 166

background image

3.5 MP920 Module Definitions

3-71

3

„

Setting Local I/O Definitions

The Local I/O Definitions determine the operation and disable status of the Module's I/O.

„

Saving, Deleting, and Closing Local I/O Definitions

Refer to the procedures in 3.3 Basic Individual Module Definition Operations for details.

Setting Item

Details

Item

Displays the I/O items.

D

Controls the register's disable setting. When the register range is set
to one word, only items 1, 3, 5, and 6 will be displayed; a "-" will be
displayed for items 2, 4, 7, and 8.

• :

Enabled

• :

Disabled

REG-No

Displays the I/O register number. When the register range is set to
one word, only items 1, 3, 5, and 6 will be displayed; a "-" will be
displayed for items 2, 4, 7, and 8.

Word

Displays the number of consecutive register words. When the regis-
ter range is set to one word, only items 1, 3, 5, and 6 will be dis-
played; a "-" will be displayed for items 2, 4, 7, and 8.

SCAN

Sets the transmission processing scan. When the register range is set
to one word, only items 1, 3, 5, and 6 will be displayed; a "-" will be
displayed for items 2, 4, 7, and 8.

• HIGH: High-speed scan
• LOW:

Low-speed scan

• (NA):

No scan specification

Current Value

In online mode, this column displays the current value of the
Machine Controller's register. The current values of discrete I/O are
displayed in binary and the current values of discrete outputs can be
changed. The current values of interrupt inputs 1 to 4 are displayed
as ON or OFF.
When a new current value is input, the value will be checked and
immediately stored in the Machine Controller

'

s register.

In offline mode, nothing will be displayed.
When the register range is set to one word, only items 1, 3, 5, and 6
will be displayed; a "-" will be displayed for items 2, 4, 7, and 8.

HEX

Displays the hexadecimal equivalent of the binary values in the Cur-
rent Value column. In offline mode, nothing will be displayed.
When the register range is set to one word, only items 1, 3, 5, and 6
will be displayed; a "-" will be displayed for items 2, 4, 7, and 8.