7.2 Setting Drawing Properties

7-9

7

Table 7.1 Data Types

7.2.6 Symbol Definition Tab Page

Click the Symbol Definition Tab in the Property Window.

„

Setting Symbol Definition Data

Click the Symbol Definition Tab in the Property Window.

Setting Item

Details

Number of Inputs

Enter a number between 1 and 16 for the number of function input
data items.

Number of Address
Inputs

Enter 1 for address input and 0 for no address input.

Number of Outputs

Enter a number between 1 and 16 for the number of function output
data items.

Input Type

Select the type of function input data. Refer to the Data Types table
after this table.

Input Comment

Enter a function input data comment of up to 8 characters.

Address Comment

Enter a function address input data comment of up to 8 characters.

Output Comment

Enter a function output data comment of up to 8 characters.

Output Type

Select the function output data type.

Selected Item

Meaning

B-VAL

Bits

I-VAL

Integers

I-REG

L-VAL

Double-length integers

L-REG

F-VAL

Real numbers

F-REG

Setting Item

Details

Symbol Name

Enter a symbol name of up to 8 characters.

No. of Register

Enter the number of the register to which to allocated the symbol.

Size

Enter the number of data items to be allocated to the symbol.

Range

Enter the symbol class.

Initial

This data is not effective in the current version.