Tab pages, The mechatrolink definitions window menus – Yaskawa MP900 Series Machine Controller for Standard Operation User Manual
Page 217

Module Configuration Definitions
3.6.7 MC350-NET Definitions
3-122
3
Tab Pages
Set the various devices connected to the MECHATROLINK network. The following four
tab pages are displayed.
When the Definitions Window for each Module is opened without any settings having been made pre-
viously, a New File Message box will be displayed. Click the OK Button to proceed to the next opera-
tion.
The MECHATROLINK Definitions Window Menus
The following table shows the functions of the menu commands on the MECHATROLINK
Definitions Window's Edit (E) menus. See 3.2.4 Module Configuration Definitions Window
Menus for details on commands on the other menus.
Setting MECHATROLINK Definitions
Transmission Parameters Tab Page
This tab page is used to set the parameters required to use the MECHATROLINK transmis-
sion system.
Tab Page
Details
Transmission Parameters
Sets the MECHATROLINK transmission parameters.
I/O Allocation
Allocates the MECHATROLINK's I/O.
I/O Map
Sets the I/O map.
Status
Displays the transmission status.
Menu Command
Function
Edit (E)
Parameter Setting (D)
Returns the allocation settings to default values.
Assignment Delete (A)
Clears the allocation settings.
Setting Item
Details
Master/Slave
Sets whether the Machine Controller is used as a Master station or a
Slave station. The MP930 can be used as a Master station only.
INFO