5 local i/o definitions – Yaskawa MP900 Series Machine Controller for Standard Operation User Manual
Page 110
3.4 MP910 Module Configuration Definitions
3-15
3
Setting Ranges for the MP910 I/O Start/End Register Numbers
1 0000 to 13FF hex (5,120 words total)
Be sure that the register numbers set for each Module do not overlap with any other Module's register
numbers.
2 With the MP910, standard register numbers have been set for each Module. We recommend using
these standard register number settings.
• LOCAL I/O: 0000 to 0001
• SVB-01: 0100 to 04FF (slot 03)
0500 to 08FF (slot 04)
Automatically set items cannot be changed.
Saving, Deleting, and Closing Module Configuration Definitions
For the saving, deleting, and closing procedures, refer to 3.3 Basic Individual Module Defi-
nition Operations.
3.4.4 Opening Individual Module Configuration Definitions Window
Set the individual Module definition data for the MP930 using the procedure in 3.3 Basic
Individual Module Definition Operations. Refer to the following for individual Module set-
ting data.
• LOCAL I/O definitions
• SVB-01 definitions
3.4.5 Local I/O Definitions
This section explains the local I/O definitions that are set for virtual slot 01.
Opening the Local I/O Definition Window
Open the following window by referring to 3.3 Basic Individual Module Definition Opera-
tions.
INFO
MP910
JEPMC-MC100/
JEPMC-MC150
CN1
CN2
I/O port
(LOCAL I/O)