Module Configuration Definitions

3.7.6 Serial Transmission Definitions

3-140

3

Leading Register Numbers and Number of Words

The leading register numbers and number of words are listed in the following table.

Default Settings for General-purpose Serial Parameters

The default setting of the serial parameters are listed in the following table.

Setting Item

Machine Controller

MP920

CP-316

CP-316H

CP-916A

CP-916G

RIO-05

Readout of Input
Relays

Leading register

IW0000

IW0000

IW0000

IW0000

IW0000

IW0000

Number of words

5120

6400

6400

2304

2304

2304

Readout of Input
Registers

Leading register

IW0000

IW0000

IW0000

IW0000

IW0000

IW0000

Number of words

5120

6400

6400

2304

2304

2304

Read/Write Coils

Leading register

MW0000

MW0000

MW0000

MW0000

MW0000

MW0000

Number of words

32768

8192

16384

3072

3072

3072

Read/Write
Holding Registers

Leading register

MW0000

MW0000

MW0000

MW0000

MW0000

MW0000

Number of words

32768

8192

16384

3072

3072

3072

Setting Item

CIR01

CIR02

Rack Number
Slot Number

01
02

01
02

Circuit Number

01

01

Transmission Protocol

MEMOBUS

MEMOBUS

Master/Slave

Slave

Slave

Device Address

01

02

Serial I/F

RS-232

RS-485

Transmission Mode

RTU

RTU

Data Length

8

8

Parity Bit

Even

Even

Stop Bit

1

1

Baud Rate

9,600

9,600

Sending (Send Delay)

None

None

Automatically
Reception
(Automatic Reception)

No

No

Readout of Input Relay IW0000/5120

IW0000/5120

Readout of Input
Registers

IW0000/5120

IW0000/5120

Readout/Write-in of
Coils

MW00000/32768

MW00000/32768

Readout/Write-in of
Hold Register

MW00000/32768

MW00000/32768

Write-in width of Coil/
Hold Register

MW00000/MW32767

MW00000/MW32767