Function
Description
Reference page
Operation Setting
Call/conversation sync
contact output
The contact output of the door station is closed
depending on their respective operations.
IP door station external
control input
When dialing operations (up to 20 digits) have been
preprogrammed into the external control input of the
N-8640DS/8650DS, such dialing operations can
be performed by closing the N-8640DS/8650DS's
contact input. Nothing operates even when
closing the contact input if no dialing operation is
preprogrammed.
Remote dial control
When the Multi interface unit's or the Direct select
unit's contact input terminal is closed, the specified
station is made to automatically perform the set dial
operation.
Direct select
This function can be used when the system's call
response mode is set to "Selective Response." After
designating the Master Station to be controlled and
assigning calling stations to the N-8000DI Direct
Select Unit's contact input and output channels, the
stations calling the designated Master Station are
indicated by corresponding lamps or other indicators.
Also, operating the desired channel enables calls
to be made between the Master Station and its
corresponding stations.
Contact bridge
Closes the Multi interface unit's or the Direct select
unit's output contact terminal when the input contact
terminal is closed.
Paging busy input
Notifies the busy status of connected external PA
paging equipment.
System diagnosis
The Multi interface unit, the Direct select unit, or the
Audio interface unit diagnoses the system condition
via the network, and provide their results at the
contact output terminal as open or closed contact.
Time signal
Automatically plays the external connected sound
source or the N-8000AF Audio interface unit's internal
sound source according to the preprogrammed
schedule.
Time correction
Synchronizes the clocks of all components in the
system with the one as a clock master. The Master
Clock transmits a sync command to all other system
equipment once a day.
Automatic daylight saving
time correction
Automatically adjusts the time for the period of
daylight saving time.
NTP client
Synchronizes the clock of the N-8000AF set to the
clock master with NTP Server. Cannot be used