7 mm*
* Approx. 5 mm for the N-8031MS/8033MS
13.15. Connector Connection
13.15.1. Mini-clamp connector connection
Connect the mini-clamp connector supplied with the N-8000EX, N-8010EX, N-8000MI, N-8000CO, N-8000AL
to a cable using a commercially available tool (pliers).
Step 1. Cut off two-cable ends in equal length, and insert them
securely to a cover section (transparent side) of the
mini-clamp connector.
Note
Insert the cable without stripping the cable jacket.
For cables, refer to
, "Type of Cable."
Step 2. With a pair of pliers, lightly pinch the mini-clamp cover
and, after ensuring that the cable is securely inserted,
firmly squeeze on the cover.
Note
Squeeze on the mini-clamp cover until it is correctly
locked.
Cover (transparent side)
Cable
Mini-clamp connector
(supplied with the
N-8000EX/8010EX/8000MI
8000CO/8000AL model
232D-02S1B-DA5
manufactured by DDK Ltd.)
Step 3. Insert the wired connector (plug) into the exchange's connector (socket) until it locks into place.
Rear panel
Note: This figure shows the N-8000EX.
For cables, refer to
, Type of Cable.
Note
Do not solder on exposed inner cables when using a stranded
wire.
13.15.2. Terminal plug connection
Step 1. Strip a cable jacket of approx. 7 mm (approx. 5 mm for the N-8031MS/8033MS only) from the cable
end.