SYSTEM SETTINGS BY SOFTWARE
Sub-station Interface: Sub-station Settings
5-57
Priority call (Selective response mode only): Set the priority level from 1 to 5 to be assigned to each
station’s "Call 1," "Call 2," or "Call 3" button. Priority level 1 is
the lowest, and Priority level 5 is the same as the priority for
the Emergency call button. The default level is 5 only for the
RS-144’s Emergency call button and 1 for all other buttons.
Notes
• The stations’ call buttons corresponding to "Call 1," "Call 2," or "Call 3" serve as function buttons as listed
below.
• "Call 2" can be set only when the RS-142, RS-144, or RS-442 is connected.
• "Call 3" can be set only when the RS-442 is connected.
Calling station indication/CCTV control
Control output:
Set the Multi interface unit's, Direct select unit's, or Audio interface
unit’s unit number and contact output terminal number, which provide
a make signal when the station is called.
Called party's station No.:
Provides a make contact when the station to be set here is called. Up
to 8 stations can be set.
Level (N-8000RS/8010RS only)
Microphone sensitivity:
Substation hands-free microphone sensitivity can be adjusted in
three increments from 1 (minimum) to 3 (maximum).
The default sensitivity is Level 2.
Speaker output:
Substation's speaker output level can be adjusted in five increments
from 1 (minimum) to 5 (maximum).
The default sensitivity is Level 3.
Call Activation - push 3 times (Sequential response mode, RS-150/160/170/450/460/470/480/442 only):
Sets whether or not to make a call by the operation of pressing the
Call button 3 times within 3 seconds.
With call tone:
Call with a call tone or without a call tone can be set.
Refusal of priority call operation:
Enables the substation to refuse priority calls from others stations.
(Sequential response mode only)
Access to emergency call operation: Sets whether or not to allow the substation to make an emergency call.
(Selective response mode only)
RS-150/160/170/180
/450/460/470/480
RS-140
RS-142
RS-143
RS-144
RS-442
Call 1
Call button
Call button
(CALL)
Call button 1 Call button
(CALL)
Emergency call button
(EMERGENCY)
Call button 1
Call 2
Call button 2
Call button 2 (NORMAL) Call button 2
Call 3
Call button 3