P. 5-22 – Toa N-8000 Series User Manual
Page 432

Chapter 5
SYSTEM SETTINGS BY SOFTWARE
General: Station Table
5-22
5.3.2. Station number and type settings
Step 1. Click "Station Table" tab to display the setting screen.
Step 2. Select the number of digits in the station number.
Step 3. Set each item as follows:
(1) Equipment No. (Can't be edited.)
Refers to the equipment number of the exchange to which stations are connected.
(2) Equipment name (Can't be edited.)
Refers to the name of the Exchange to which stations are connected.
(3) line No. (Can't be edited.)
Refers to the number of the line to which stations are connected.
(4) Type
Allows the type of station to be selected. Setting contents change depending on the type of station selected.
(5) Station No.
Refers to the station number used when making a call. Set the number with the same digit length (2 – 6
digits) as that in the Station Number Digit setting.
When an identification number is used in the multi-interface unit or C/O line interface unit, station numbers
beginning with the same identification number (including the 2-digit identification number) cannot be used.
Example: When the access number is "10," "110" and "1100" can be used but "10," "100," "101," or "1000"
cannot be used for station numbers.
Note
If you set the station number starting with "0" (such as 01 or 0001), enter the station number exactly as
registered without omitting "0" in the item requiring the station number entry (e.g. Master station calls from
the door station and Substation).