P. 5-55 – Toa N-8000 Series User Manual
Page 465

Chapter 5
SYSTEM SETTINGS BY SOFTWARE
Sub-station Interface: Function Settings
5-55
Paging time-out:
Set whether to limit the duration of paging call with the station. If setting a time-
out, enter the time limit after which paging calls to the station are automatically
terminated.
If not setting a time-out, paging calls will continue until executing the termination
operation.
(3) paging with call tone (N-8400RS only)
Sounds a pre-announcement tone when paging is initiated.
(4) Delay Time
Set the delay time before paging is initiated.
(5) paging response mode (N-8400RS only)
Select either “Zone Selection” or “Automatic response” modes when responding to the paging.
Zone Selection:
Responds to a paging call by designating the number of the paging zone. Respond
to the paging party who made the paging to the designated zone last is called. Use
this mode if paging announcements are heard from multiple zones.
Automatic response: Use only the paging response key to make a response. The responding station
is connected to the station that made a paging call over the paging zone through
which the responding station last received a call.
(6) Calling station indication
Select either “During call and talk” or “During talk” mode when performing the calling station indication
function.
The table below shows the timing that the Multi interface unit’s, Direct select unit’s, or Audio interface unit’s
contact output is closed.
(N-8400RS only)
Calling station indication
Station operation
Calling
Being called
Call waiting
Talking
Being paged
Receiving scan monitor
During call and talk
During talk
Open
Open
Open
Closed
Open
Closed
Closed
Closed
Closed
Closed
Open
Closed