Chapter 5
SYSTEM SETTINGS BY SOFTWARE
C/O Interface: Function Settings 2
5-90
Step 2. Set individual items.
(1) C/O Setting
Name:
Set the name of the C/O line.
(2) Timeout
Timeout:
Set the time interval for automatic termination of conversations ( 1 – 99 min).
Scan monitor timeout:
Set the time interval for automatic termination of scan monitoring ( 1 – 99 min).
Paging time-out:
Set whether to limit the duration of paging call with the station. To set a timeout,
enter the time limit after which paging calls to the station are automatically
terminated.
If a time-out is not set, paging calls will continue until executing the termination
operation.
(3) Call/Transfer
Access No:
Select the identification number (from 0 to 99) to be dialed when making a call
to the C/O line.
Note
When a single digit number is set for the access number, avoid using numbers
that match the first 1 digit of station numbers.
When a double digit number is set for the access number, avoid using numbers
that match the first 2 digits of station numbers.
Dial of transfer to:
Set a telephone number of up to 32 digits to be used when a call is transferred
through the C/O line interface unit.
(4) Direct in line/dial
Access to direct in dial:
Set whether to enable or disable direct inward dialing operation.
Access to direct in line:
Set whether to enable or disable direct in line operation.
Leader:
Set the master station to be called up.
Step 1. Click "Function Settings 2" tab to display the following setting screen.