Direct select unit connection – Toa N-8000 Series User Manual
Page 373

3-69
Chapter 3
INSTALLATION & WIRING
13.8. Direct Select Unit Connection
[General description of connection]
For cables, refer to
1. Power supply connection
Connect the supplied power supply cord to AC
Mains or a UPS (Uninterruptible power supply).
About power supply cord handling
The supplied power supply cord is designed for
exclusive use with the N-8000DI.
Never use it with other equipment.
2. Contact input terminal connection
(Refer to
, Terminal plug connection.)
[Specification of no-voltage make contact input]
Short-circuit current: 5 mA
Open-circuit voltage: 24 V
* Select an appropriate UPS taking into consideration the total power consumption of all system components
and the required backup time. On-line uninterruptible power supply (UPS) is recommended.
Reference
Direct select unit: 16 W (rated) for CE version, 16 W (rated) for CU version
8-Port 10M/100M Switching Hub: 10 W (Differs depending on products.)
1
2
2
2
2
Be sure to ground.
To AC mains or a UPS
(Uninterruptible power supply system)*
Note
If there is a danger of lightning strikes,
insert an appropriate surge arrester
into the power line.
*
1
10P removable terminal plug
(supplied with the N-8000DI)
*
1
Contact input signals
Contact input signals
Contact input signals
Contact input signals
N-8000DI Direct select unit