Time signal, Time correction, Automatic daylight saving time (summer time) – Toa N-8000 Series User Manual
Page 302: Correction, P. 2-191

2-191
Chapter 2
FUNCTIONS AND OPERATION
OTHER FUNCTIONS (CONVENIENT FUNCTIONS)
18. TIME SIGNAL
(Refer to
, "Time Signal".)
19. TIME CORRECTION
Synchronizes the clocks of all components in the system with the one as a clock master.
The Master Clock transmits a sync command to all other system equipment once a day.
Use the supplied N-8000 Setting Software for the Master Clock setting.
Network
N-8000AF
N-8000EX
N-8000MI
N-8000AF
20. AUTOMATIC DAYLIGHT SAVING TIME (SUMMER TIME) CORRECTION
Daylight saving time (summer time) can be supported and the following settings performed using the N-8000
Setting Software.
• Automatic daylight time correction ON/OFF
• Daylight time start setting (month, week, day, hour)
• Daylight time end setting (month, week, day, hour)
The daylight saving time correction will start or end at the set [hour] of nth [day] of [week] of [month].
The last day of the week in the month can also be designated.
Notes
• Only the N-8000AF for which the Time Sync function has been enabled can be set as the master clock.
• The N-8000RS, N-8010RS and N-8400RS Substation interface units cannot be set as the master clocks.
• When the NTP Client function (see
) of the N-8000AF set to the clock master is enabled, it is
recommended to synchronize the N-8000AF’s clock with NTP server first, then to perform time correction.