5.3.7. Time signal temporary exception
Any station can be temporarily excepted from the time signal-initiated paging destinations through key operations
at the master station.
Up to 10 stations can be simultaneously excepted through a single operation.
Once registered for temporary exception, the stations will not accept any time signal-initiated paging calls until
exception cancellation is performed to those stations.
[Time signal temporary exception: Registration]
9
+
3
+
X
+
+
+
X
+
Function designation No.
Station No.
Station No.
(confirmation tone)
+
Max. 10 units
+
Designate the station number in the station number digits (2 − 6) preset by the N-8000 Setting Software.
[Time signal temporary exception: Cancellation]
9
+
4
+
+
Function designation No.
(confirmation tone)
All temporary exception registrations are cancelled.
5.3.8. Reserving the time signal schedule change
System Time Signal schedule change can be reserved through key operations at any station.
To set the reserved day, designate the day from one (next day) to 9 days later after performing the reservation
operation by number (1 − 9).
The reserved schedule is executed at 00:00 AM on the reserved day.
9
5
X
Y
Y
+
+
Function designation No.
(confirmation tone)
+
+
+
Schedule No.
(01 – 16)
Reserved day
(1 – 9)