5.14. paging Zone Settings
Step 1. Click "Paging" to display the following setting screen.
Step 2. Select the paging number digit.
Select the number for [Paging No. digit].
Zones are automatically indicated depending on which number is set.
The maximum number of zones is 192.
Step 3. Enter the paging port number to be used.
Enter the start paging port number to be used in the system. The valid range is from 1 to 65535. The
N-8000 system uses (the number of Exchanges) x 4, (the number of various kinds of interface units) x
4 and (the number of IP Stations) x 4 consecutive ports starting with the start port.
Note
Take care not to duplicate the number with the UDP port number set on
,
,
, and 15000 that is internally used.
Step 4. Enter a zone name.
Double-clicking the cell (pag 1 – ) located above the zone number allows the zone name to be edited.
The zone name can be up to eight characters long.