Sub stations – Toa N-8000 Series User Manual
Page 398

4-10
Chapter 4
SYSTEM DESIGN FLOW
5.4. Sub Stations
Side TAB
Item
Default
Reference
page
Network settings
IP address *
1, 2
192.168.1.1
SW:
BR:
Subnet Mask *
1, 2
255.255.255.0
Default Gateway *
1, 2
0.0.0.0
Web server port number *
1, 2
80
SW:
BR:
TCP start port number
5000
UDP start port number
5006
Multicast port number
6000
NAPT compatible
Incompatible
Network ID
1
WAN IP address
192.168.1.1
WAN Web server port number
80
WAN TCP start port number
5000
WAN UDP start port number
5006
Broadcast specification
High quality sound
transmission mode
Communication capacity
2990 kbps
Function settings
Call time-out
No limit
Conversation time-out
No limit
Paging time-out
No limit
Paging response mode
Zone selection
Calling station indication
During call and talk
Sub-station-interface
Selection
Call master Call 1
-
Call master Call 2
-
Call master Call 3
-
Call volume
3
Sub-station Selection Line No.
-
Sub-station Selection Sub-station No.
-
Sub-station Selection Sub-station
name
-
Priority Level (Call 1)
1 (5 for RS-144 only)
Priority Level (Call 2)
1
Priority Level (Call 3)
1
Microphone sensitivity
2
Speaker output
3
Control output / MI/DI/AF equipment No.
-
Control output / Contact output No.
-
Called station's No.
-
Call Activation - push 3 times
OFF
with call tone
ON
Refusal of priority call operation
OFF
Access to emergency call operation
OFF
• All of the above items can be set on the N-8000 Setting Software.
*
1
Be sure to set this since settings and conversations are performed via a network.
*
2
Settings possible from a browser as well.