N-8033ms flush-mount master station – Toa N-8000 Series User Manual
Page 622

8-22
Chapter 8
APPENDIX
5.9. N-8033MS Flush-Mount Master Station
* 0 dB = 1 V
Note: The design and specifications are subject to change without notice for improvement.
• Accessories
Back Box: YC-841
• Optional product
Machine screw M4 x 35 ................................................................................ 4
Acoustic material .......................................................................................... 1
Removable terminal plug (2 pins, preinstalled on the unit) .......................... 1
Power Source
48 V DC (supplied from the IP intercom exchange)
Power Consumption
1.8 W (at rated), 2.4 W (max.)
Wiring Method
1 set of twisted pair cable
Transmission System
2 wire 160 kbps echo canceller transmission system
Signal Level
Under 0 dB*
Speech Method
Hands-free conversation
Audio Frequency Range
300 Hz – 7 kHz
Transmission Range
Max. 1500 m (ø0.65 mm, Loop resistance 170 Ω)
Hands-free
Speaker:
5.7 cm cone-type, 0.6 W, 8 Ω
Microphone: Omni-directional electret condenser microphone
Indication
Status indicator
Line Connecting Terminal
Pin header (2 pins)
External Dial Input
No-voltage make contact input, open voltage: 5 V DC, short-circuit
current: 1 mA, screwless connector (5 pins)
Installation Method
Flush-mount/Surface-mount
Operating Temperature
0 to 40 °C
Operating Humidity
Under 90 % (no condensation)
Dust/Water Protection
IP65 (Note that panel edges must be sealed at installation.)
Resistance to Environment
Passed our chemical-resistant test
Finish
Membrane switch: Polyester film
Dimensions
115 (w) x 254 (h) x 51 (d) mm
Weight
850 g