P. 5-103 – Toa N-8000 Series User Manual
Page 513

Chapter 5
SYSTEM SETTINGS BY SOFTWARE
Audio Interface: Network Settings
5-103
(4) port No.
Set the start port number to be used for each protocol.
[Web server]
Allows entry of the Web server's port number. The valid range is from 1 to 65535. The default factory setting
is 80.
[TCP port]
Allows entry of a TCP port start number other than the Web server (valid range from 1 to 65532). The
N-8000 system uses 4 consecutive ports starting with the TCP start port. The default factory setting is
5000.
The TCP port is assigned as follows.
Note
Because UDP port number 15000 is used internally by the system, the numbers from 14981 to 15000 are
not available.
[Paging port (UDP)]
Displays the UDP port number to be used when making paging using the multicast communications.
To perform settings, refer to
p. 5-121, Paging Zone Settings
(5) NApT compatible
When connecting a PC to the Audio interface unit using the global IP address, mark the [Enable] checkbox
to make the items from [Network ID (6)] to [WAN port No. (8)] available for input.
Port
Web server
Call control
PC monitoring
PC control
Reservation
Port Number
Web server
Port start number + 0
Port start number + 1
Port start number + 2
Port start number + 3
Protocol
TCP
TCP
TCP
TCP
TCP
Default setting
80
5000
5001
5002
5003
Port
Reservation
Conversation
Port Number
Port start number + 0 to 3
Port start number + 4 to 19
Protocol
UDP
UDP
Default setting
5006 to 5009
5010 to 5025
[UDP port]
Allows entry of UDP port start number to be used (valid range from 1 to 65516). The N-8000 system uses
20 consecutive ports starting with the UDP start port. The default factory setting is 5006.
The UDP port is assigned as follows.