Toa N-8000 Series User Manual
Page 380

3-76
Chapter 3
INSTALLATION & WIRING
LAN
CONTACT IN
C H
N-8510MS rear
To network
To AC mains
To external control equipment
such as a switch or sensor
1
2
3
Cable
Ferrite clamp
(supplied with the N-8510MS)
13.12.2. N-8510MS connection
1. AC adapter terminal connection
Connect the AC adapter*.
Install the supplied ferrite clamp on the AC adapter
cable by winding the cable around the ferrite clamp
once.
* Use the AC adapter AD-1210P/1215P (optional) or
the equivalent.
As for the usable adapter, consult your TOA
dealer.
2. Message start terminal connection
3. Network connection terminal connection
Can be connected to a network of 10BASE-
T/100BASE-TX in auto-sensing.
Connecting the station to a PoE (Power over
Ethernet) switching hub compliant with IEEE802.3af
eliminates the need for an AC adapter. (For
connection, refer to the instruction manual supplied
with the switching hub.)
Use a straight through cable of UTP category 5 or
more for this connection.
11 mm
COM
HOT
Press down the desired push-
in terminal button with a tip of
standard driver, and insert the
cable securely.
For the type of cables, refer
to
For the type of cables, refer
to
, Type of Cables.