P. 5-100 – Toa N-8000 Series User Manual
Page 510

Chapter 5
SYSTEM SETTINGS BY SOFTWARE
Telephone Interface: Function Settings 2
5-100
(4) Door remote
Set the Multi interface unit's, Direct select unit's, or Audio interface unit’s unit number and contact output
terminal number to be used for door remote control.
(5) Calling station indication/CCTV control
Control output :
Set the Multi interface unit's, Direct select unit's, or Audio interface unit’s unit number
and contact output terminal number, which provide a make contact when the station
is called.
Called station's No.: Provides a make contact when the station to be set here is called. Up to 8 stations
can be set.
When the C/O interface unit is set as a called station, enter "#", followed by the
access number. For example, when setting the C/O interface unit with access
number "05," enter "#05".
(Example)
The operation example illustrated below is based on the following settings:
Station No. (for Station): 148
Control Output
MI Equipment No.: 5
Contact output No.: 6
Called station's No.: 149
(6) Record conversation
Records Telephone interface conversations.
The conversation of the Telephone interface is provided from the audio output of the designated N-8000AF
audio interface unit.
(7) User Access Code
Sets whether or not to enable the Access code authentication.
Enter the access code number (4-digit number).
(8) Access to priority call operation
Enables the station to initiate priority calls.
This function can only be used when the system has been set for sequential response mode.
(9) Access to paging call operation
Enables or disables paging calls from the station.
(10) Access to emergency all paging call operation
Enables or disables emergency all paging calls from the station.
(11) External equipment control
Set whether the one-shot make contact output or make/break contact output is operated at the station.
Call
No. 148
No.149
1
4
9
N-8000MI (Equipment No. 5)
Contact Output No. 6
Make contact
The Multi interface unit's (equipment No. 5) Contact No. 6 closes when the station No. 148 calls the station