Remote dial control, Only when the n-8000mi/8000di is used), P. 2-187 – Toa N-8000 Series User Manual
Page 298

2-187
Chapter 2
FUNCTIONS AND OPERATION
OTHER FUNCTIONS (CONVENIENT FUNCTIONS)
13. REMOTE DIAL CONTROL
(only when the N-8000MI/8000DI is used)
When the N-8000MI/8000DI's contact input terminal is closed, an arbitrary station is made to automatically
perform dial operation. A set of up to 32 dial codes (including dial numbers and key operations) can be assigned
to each contact input terminal.
For example, signals from a sensor can automatically activate a station to make a call as shown below.
Use the supplied N-8000 Setting Software to perform settings for the Remote dial control. (Refer to
.)
Note
To perform the remote dial control, the contact input terminal needs to be closed for over 50 ms.
[Example]
No. 200 station automatically calls the No.100 station by means of a make contact input to the N-8000MI/8000DI
from a sensor.
No. 100
No. 200
Calls No. 100.
Remote control activation
N-8000MI/8000DI
Sensor, etc.
Make contact
1
0
0
Call tone