13.3. N-8000RS/8010RS Substation Interface Unit Connection
[General description of connection]
For cables, refer to
1. Power supply connection
Connect the supplied power supply cord to AC
Mains or a UPS (Uninterruptible power supply).
About power supply cord handling
The supplied power supply cord is designed for
exclusive use with the N-8000RS/8010RS.
Never use it with other equipment.
2. Substation, Switch panel, or Switch board
Connections
(Refer to
, Terminal plug connection.)
3. Network connection
Can be connected to a network of 10BASE-
T/100BASE-TX in auto-sensing.
Use a straight through cable of UTP category 5 or
more for this connection.
* Select an appropriate UPS taking into consideration the total power consumption of all system components
and the required backup time. On-line uninterruptible power supply (UPS) is recommended.
Reference
N-8000RS: 40 W (rated) for CE version, 35 W (rated) for CU version
N-8010RS: 30 W (rated) for CE version, 25 W (rated) for CU version
8-Port 10M/100M Switching Hub: 10 W (Differs depending on products.)
1
2
3
Note: This figure represents the RS-160/170.
To AC mains or a UPS
(Uninterruptible power supply
system)*
Note
If there is a danger of lightning
strikes, insert an appropriate
surge arrester into the power line.
Be sure to ground.
3P removable terminal plug
(supplied with the N-8000RS
/8010RS)
2-core shielded cable
To network
RJ-45 connector
Orange (A)
Brown (B)
Black (C)
N-8000RS/8010RS Substation interface unit
16 lines
RS-150, RS-160,
RS-170, or RS-180
RS-140, RS-142, RS-143, or RS-144
Note: This figure represents
the RS-140.
2-core shielded cable
Brown (A)
Orange (C)
Red (B)
Brown
Orange
Red