Chapter 5
SYSTEM SETTINGS BY SOFTWARE
Direct Select: Network Settings
5-112
(4) port No.
Set the start port number to be used for each protocol.
[Web server]
Allows entry of the Web server's port number. The valid range is from 1 to 65535. The default factory setting
is 80.
[TCP port]
Allows entry of a TCP port start number other than the Web server (valid range from 1 to 65532). The
N-8000 system uses 4 consecutive ports starting with the TCP start port. The default factory setting is
5000.
The TCP port is assigned as follows.
Port
Web server
Call control
PC monitoring
PC control
Reservation
Port Number
Web server
Port start number + 0
Port start number + 1
Port start number + 2
Port start number + 3
Protocol
TCP
TCP
TCP
TCP
TCP
Default setting
80
5000
5001
5002
5003
(5) NApT compatible
When connecting a PC to the Direct select unit using the global IP address, mark the [Enable] checkbox to
make the items from [Network ID (6)] to [WAN port No. (8)] available for input.
WAN
LAN
LAN
Router
NAPT
Router
NAPT
(6) Network ID
When connecting a PC to the Direct select unit using the global IP address, enter the number that identifies
networks for each range accessible by the PC using the local address.
When networks are connected as shown below, for example, assign different ID numbers for each, such as
"1" to equipment connected to LAN (1) and "2" to equipment connected to LAN (2).
Network ID No. 1 is assigned to the PC for setting. Set network ID No. 1 to equipment that can be accessed
by the PC (for example, equipment connected to LAN 1) using the local address.
(7) WAN Ip address
Allows entry of the Direct select unit's IP address as viewed from the WAN side.