5.33. RS-470 Outdoor Vandal-Resistant Substation
Note: The design and specifications are subject to change without notice for improvement.
• Accessories
No.6-32UNC x 18 .................................................. 4
Machine screw M4 x 25 ......................................... 4
Call Button
Momentary (Emergency call: Press twice within 400 ms.)
Rated Input
1 W
Internal Speaker
Cone-type
Internal Microphone
Electret condenser type
Wiring
Twisted pair cables (2-pair)
Transmission Range
1000 m/ø0.5 mm (AWG24), 1500 m/ø0.65 mm (AWG22),
2000 m/ø0.9 mm (AWG19)
Operating Temperature
–10 to +50°C (Temperature range not to freeze the speaker and switch)
Housing Protection
BS EN62262: 2002: IK02 equivalent
Dust/Water Protection
IP54
Finish
Panel:
Stainless steel, hairline
Call button: Metal, silver
Circuit board: Weather-resistant coating
Dimensions
120 (w) x 120 (h) x 49.5 (d) mm
Weight
550 g
Applicable Box
2-gang electrical box: YC-302 (option)
5.34. RS-480 Emergency Substation
Note: The design and specifications are subject to change without notice for improvement.
• Accessories
No.6-32UNC x 18 .................................................. 4
Machine screw M4 x 25 ......................................... 4
Call Button
Momentary (Emergency call: Press twice within 400 ms.)
Rated Input
1 W
Control Output
Open collector, Maximum controlled voltage: 30 V DC, Control current: 30 mA
Internal Speaker
Cone-type
Internal Microphone
Electret condenser type
Indicator
When called: Status indicator (red) flashing
In conversation: Status indicator (red) lit
Wiring
Twisted pair cables (2-pair)
Transmission Range
1000 m/ø0.5 mm (AWG24), 1500 m/ø0.65 mm (AWG22),
2000 m/ø0.9 mm (AWG19)
Operating Temperature
–10 to +50°C (Temperature range not to freeze the speaker and switch)
Housing Protection
BS EN62262: 2002: IK02 equivalent
Dust/Water Protection
IP54
Finish
Panel:
Stainless steel, hairline
Call button: Metal, red
Circuit board: Weather-resistant coating
Dimensions
120 (w) x 120 (h) x 50.5 (d) mm
Weight
575 g
Applicable Box
2-gang electrical box: YC-302 (option)