N-8640ds ip door station – Toa N-8000 Series User Manual
Page 629

8-29
Chapter 8
APPENDIX
5.16. N-8640DS IP Door Station
Note: The design and specifications are subject to change without notice for improvement.
UNC No.6-32 x 20 ................................................. 4
Machine screw M4 x 20 ......................................... 4
Waterproof washer ................................................ 4
LAN coupler .......................................................... 1
• Accessories
Back box:
YC-150 (For flush mounting)
Wall-mount Box: YS-13A (For surface mounting)
AC adapter:
AD-1210P or AD-1215P
• Optional products
Power Source
Power supply device that complies with IEEE802.3af standard or 12 V
DC (supplied from the AC adapter)
Power Consumption
Use of the AC adapter (12 V DC): 3.5 W (station only)
Use of the PoE (48 V DC):
5 W
Speech Method
Hands-free conversation
Audio Frequency Range
300 Hz – 7 kHz
Hands-free
Speaker:
3.5 cm cone-type, maximum output 0.5 W, 8 Ω
Microphone: Omni-directional electret condenser microphone
Contact Input
1 channel, no-voltage make contact input, open circuit voltage: 5 V DC,
short circuit current: 10 mA or less, unterminated ends
Contact Output
Open collector output, withstand voltage: 30 V DC,
control current: Max. 50 mA (4 output 1 COMMON) unterminated ends
Relay contact output, 1 channel, withstand voltage: 30 V DC,
control current: Max. 500 mA, unterminated ends
External Speaker Terminal
Maximum output 0.5 W, 8 Ω, unterminated ends
Network Section
Network I/F
10BASE-T/100BASE-TX (Automatic-Negotiation)
Network Protocol
TCP/IP, UDP, HTTP, RTP, ARP, ICMP, IGMP
Audio Packet Transmission
System
Unicast, Multicast
Number of Paging
Destinations
0
Note: Reception only
Connector
RJ-45 connector (PoE compatible)
Voice Sampling Frequency
16 kHz, 8 kHz (controllable on the software)
Quantifying Bit Number
16-bit
Voice Encoding Method
Sub-band ADPCM, Cryptosystem
Voice Packet Loss Recovery Silence insertion
Audio Delay Time
80 ms, 320 ms (controllable on the software)
Indication
Status indicator
Installation Method
Flush-mount/Surface-mount
Operating Temperature
–10 to +50 °C
Operating Humidity
Under 90 % RH (no condensation)
Housing Protection
BS EN62262: 2002: IK02 equivalent
Dust/Water Protection
IP65 (Note that panel edges must be sealed at installation.)
Finish
Plate:
Stainless steel (SUS304), hairline
Call button: Metal
Dimensions
115 (w) x 162 (h) x 58.5 (d) mm
Weight
780 g