N-8020ms industrial-use master station – Toa N-8000 Series User Manual
Page 620

8-20
Chapter 8
APPENDIX
5.6. N-8020MS Industrial-Use Master Station
* 0 dB = 1 V
Note: The design and specifications are subject to change without notice for improvement.
Rubber cap ............................................................ 2
• Accessories
Wall mounting bracket: YC-280
• Optional product
Power Source
48 V DC (supplied from the IP Intercom exchange)
Power Consumption
1.8 W (at rated), 2.4 W (max.)
Wiring Method
1 set of twisted pair cable
Transmission System
2 wire 160 kbps echo canceller transmission system
Signal Level
Under 0 dB*
Speech Method
Hands-free or handset conversation
Audio Frequency Range
300 Hz – 7 kHz
Transmission Range
Max. 1500 m (ø0.65 mm, Loop resistance 170 Ω)
Hands-free
Speaker:
5.7 cm cone-type, 0.6 W, 8 Ω
Microphone: Omni-directional electret condenser microphone
Handset
Receiver path: Dynamic type
Send path:
Electret condenser microphone
Dial-in Contact Output
Open collector output (polarized), withstand voltage: Max. 30 V DC,
control current: Max. 50 mA, screwless connector (2 pins)
Indication
Status indicator
Line Connecting Terminal
RJ-11 modular jack
External Speaker Terminal
0.6 W, 8 Ω, screwless connector (2 pins)
Installation Method
Desk/Surface mounted master station
(When mounting to the wall, use the optional YC-280.)
Operating Temperature
–10 to +50 °C
Operating Humidity
Under 90 % RH (no condensation)
Dust/Water Protection
IP54
Finish
Body, Handset: ABS resin, gray
Dimensions
170 (w) x 220 (h) x 97.8 (d) mm
(excluding a curl cord and projection sections)
Weight