13.12.4. N-8610RM connection
LAN
DC INPUT
12V
200mA
N-8610RM rear
To network
To AC mains
1
2
1. AC adapter terminal connection
Connect the AC adapter*.
* Use the AC adapter AD-1215P (optional) or the
equivalent.
As for the usable adapter, consult your TOA
dealer.
Note
Install the supplied ferrite clamp (black) on the AC
adapter cable by winding the cable around the
ferrite clamp once.
2. Network connection terminal connection
Can be connected to a network of 10BASE-
T/100BASE-TX in auto-sensing.
Connecting the station to a PoE (Power over
Ethernet) switching hub compliant with IEEE802.3af
eliminates the need for an AC adapter. (For
connection, refer to the instruction manual supplied
with the switching hub.)
Use a straight through cable of UTP category 5 or
more for this connection.
Note
Install the supplied ferrite clamp (gray) on the LAN
cable by winding the cable around the ferrite clamp
once.
Cable
Ferrite clamp (black, supplied
with the N-8610RM)
LAN cable
Ferrite clamp (gray, supplied
with the N-8610RM)