Wiring, Exchange connection – Toa N-8000 Series User Manual
Page 357

3-53
Chapter 3
INSTALLATION & WIRING
13. WIRING
13.1. exchange Connection
N-8000EX/8010EX Exchange
To AC mains or a UPS
(Uninterruptible power supply system)*
16 lines
Note
Be sure to ground.
Both upper and lower terminals (clip terminals)
are internally connected.
Mini-clamp connector
232D-02S1B-DA5 (DDK)
(Supplied with the N-8000EX/8010EX)
Lines should be twisted
E-7000TB
Terminal board
Station
If there is a danger of lightning strikes,
insert an appropriate power gap arrester
into the power line.
* Select an appropriate UPS taking into consideration the total power consumption of all system components
and the required backup time. On-line uninterruptible power supply (UPS) is recommended.
Reference
Exchange: 50 W (rated)
8-Port 10M/100M Switching Hub: 10 W (Differs depending on products.)
Note
Once the station line connected between a station and the
exchange is short-circuited or a ground fault occurs on the
cable, power cannot be supplied to the station even when
the short or ground fault is removed.
To restore the situation, be sure to disconnect the cable
connector at the station or exchange, and then connect it
again after several seconds.