Multi-operation activation, P. 2-39, Xy y y – Toa N-8000 Series User Manual
Page 150: Xz z z, X3 b b b

2-39
Chapter 2
FUNCTIONS AND OPERATION
MASTER STATION'S FUNCTIONS AND OPERATION
X
X
Y
Y
Y
SX-2000 system ID
number (01 – 08)
SX-2000
zone number*
2
(001 – 256)
X
X
Z
Z
Z
Zone pattern number*
3
(001 – 216)
SX-2000 system ID
number (01 – 08)
X
X
3
B
B
B
SX-2000 system
ID number (01 – 08)
Control pattern number*
2
(001 – 162)
4.5. Multi-Operation Activation
4.5.1. Simultaneously activating selected zone broadcast and control output pattern
Broadcasts to the SX-2000 zone (individual zone or zone pattern*
1
) and SX-2000 system's control output
activation can be performed at the same time.
Broadcast durations can be limited by preprogramming the time limit (between 1 and 20 minutes in 1-minute
units) for each station.
*
1
A pattern into which multiple zones are grouped.
Notes
• Perform zone pattern settings using the N-8000 Setting Software. You can also import and use the output
zone pattern having been set on the SX-2000 Setting Software. (Refer to
.)
• Set the time limit (Time out) using the supplied N-8000 Setting Software. (Refer to
.)
Step 1. Press the Paging key.
Step 2. Select a zone.
Multiple zones or zone patterns can be sequentially selected by repeating the key operation in the
following step 2-1 or 2-2.
Note
The maximum number of digits for zone selection dial is 380.
2-1. When selecting a zone
Press the following keys in order.
2-2. When selecting a zone pattern
Press the following keys in order.
Step 3. Select the control pattern set for the control output function.
Press the following keys in order.
Multiple control patterns can be selected by repeating the above key operation.
*
4
The pattern number having been set using the N-8000 Setting Software.
*
3
The pattern number having
been set using the N-8000
Setting Software.
*
2
Z
one numbers are assigned as shown in
the table below.
Zone
No.
SX-2000AO's
unit No.
SX-2000AO's
audio output
terminal No.
001
1
1
002
1
2
...
...
...
008
1
8
009
2
1
...
...
...
256
32
8