Time signal, Audio trigger – Toa N-8000 Series User Manual
Page 109

1-92
Chapter 1
GENERAL DESCRIPTION
11.5. Time Signal
This function pagings set sound sources to set paging zones according to preprogrammed schedules using
the N-8000AF Audio Interface. The operation mode of one of the Audio Interfaces in the system must be set to
"Time Signal," and "Events" (time, paging zone, sound source, etc.) and "Schedules," which are combinations
of various "Events," must be preprogrammed to automatically operate the Time Signal function.
N-8000AF
Chime tone
Chime tone
12
9
Sun
9:00
12:00
Mon
Morning chime Morning chime Morning chime Morning chime Morning chime
Lunch break
Lunch break
Lunch break
Lunch break
Lunch break
Tue
Wed
Thu
Fri
Sat
11.6. Audio Trigger
Alarm operation is activated if audio that enters the preprogrammed N-8050DS Door Station's or
N-8640DS/8650DS IP Door Station's microphone meets set conditions.
Only the N-8000EX Exchange can support this function, and up to four Door Stations that enable Audio Trigger
alarm operation can be connected per Exchange. The Audio Trigger function cannot be used for stations that
are set to receive background music. The Door Station detects input audio when it is in standby mode.
Preprogrammed Master Station calls can be generated or the contact terminal of the preprogrammed N-8000MI
Multi-Interface Unit or N-8000DI Direct Select Unit can be closed upon alarm operation (closure by one-shot
pulse). In addition, audio detected by the Door Station can be heard at the preprogrammed Master Station's
hands-free speaker for a set period of time after Audio Trigger detection.
N-8050DS/8640DS/8650DS
Crack!!
Call tone
Call generated