Contact input and output functions – Toa N-8000 Series User Manual
Page 106

1-89
Chapter 1
GENERAL DESCRIPTION
11.4.2. Remote dial control
When the N-8000MI's or the N-8000DI's contact input terminal is closed, a station is made to automatically
perform dial operation. A set of up to 20 dial codes (including dial numbers and key operations) can be assigned
to each contact input terminal.
For example, signals from a sensor can automatically activate a station to make a call as shown below.
Note
To perform the remote dial control, the contact input terminal needs to be closed for over 50 ms.
No. 100
No. 200
Calls No. 100.
Remote control activation
N-8000MI/8000DI
Make contact
1
0
0
Call tone
Sensor, etc.
11.4. Contact Input and Output Functions
The following functions can be realized by using the N-8000MI's, the N-8000DI's, or N-8000AF's contact input
and output. However, the functions that can be realized are different depending on the models as shown in the
table below.
Function Unit N-8000MI
N-8000DI
N-8000AF
External equipment
control
Remote dial control
x
Contact bridge function
x
Paging busy input
x
x
System diagnosis
Direct select
x
x
: Usable
x : Not usable
Calling station indication/
CCTV interlock
11.4.1. External equipment control
External equipment can be controlled by a one-shot make signal or a make/break signal provided at the
N-8000MI's, the N-8000DI's, or the N-8000AF's contact output through either interlock with received calls or
station operation. Such control includes door remote control, calling station indication control, and hospital
waiting status indication control.
N-8000MI/8000DI/8000AF
Make contact
External equipment