Time signal (only when the n-8000af is used), P. 2-50 – Toa N-8000 Series User Manual
Page 161

2-50
Chapter 2
FUNCTIONS AND OPERATION
MASTER STATION'S FUNCTIONS AND OPERATION
5.3. Time Signal
(only when the N-8000AF is used)
The Time Signal function broadcasts preset sound sources over preset paging zones according to
preprogrammed schedules. The N-8000AF Audio Interface of which operation mode has been set to "Time
Signal" outputs the time signals.
5.3.1. Time signal event
• Event settings must be performed to automatically start the Time Signal function. Set events are recorded in
the N-8000AF.
• To perform event settings, the N-8000AF's operation mode must be set to "Time Signal."
• Only one (1) N-8000AF in the system can be set to "Time Signal" operation mode.
Note
Use the supplied N-8000 Setting Software to perform Time Signal settings, including events and schedules.
(Refer to
.)
[Internal timer-initiated event settings]
• Up to 1,024 events can be set.
• Individual events are assigned to a maximum of 16 schedules (up to 64 events per schedule).
Event
Event
Event
Event
Event
Event
Schedule
Up to 64
Up to 16
Schedule
• Each event is comprised of the following contents: Time (in second unit
s), day of week (multiple days
selectable), paging zones (up to 10 zones selectable from 192 zones), soun
d source number (selected from
0 − 9) and external equipment control (ON or OFF).
• The function of each sound source number is as follows:
0: Silent
1: Internal sound source 1 (Trill tone)
2: Internal sound source 2 (Bell 1)
3: Internal sound source 3 (Bell 2)
4: Internal sound source 4 (Chime Tone 1)
5: Internal sound source 5 (Chime Tone 2)
6. External sound source 1 (N-8000AF's Contact Output 1 activated)
7. External sound source 2 (N-8000AF's Contact Output 2 activated)
8. External sound source 3 (N-8000AF's Contact Output 3 activated)
9. External sound source 4 (N-8000AF's Contact Output 4 activated)
• Set the sound source activation time (1 − 99 sec.).