To Learn an R-MEM Register:
1.
Enable the switcher sources to be affected by R-MEM in the right pane.
Selected switcher source buttons are green on the left. Only the selected
sources will be saved to the R-MEM. You can use the
Enable All
and
Disable All
buttons above to select all or none of the switcher sources.
2.
If you want the register to use Auto Recall, touch the
Auto Recall
button
so its indicator illuminates.
3.
Touch the
Learn
button in the Mode pane.
4.
Touch the numbered Bank and Register buttons in the center pane to
save the information to the selected register. Touch the bank button
first if you are saving to a different bank. If the desired bank is already
selected, you can touch just the Register button.
To Recall an R-MEM Register
1.
Make sure the Preview mode button is not selected.
2.
Turn the
Auto Recall
button on or off to control how the register is
recalled.
3.
Touch the Bank and Register buttons for the desired register. Touch the
bank button first if you are recalling from a different bank, or just touch
the Register button if in the same bank.
a.
If the
Auto Recal
l button is on, the sources selected at the time the
register was saved (with
Auto Recall
on) will be changed to the
R-MEM values of that register. If
Auto Recall
was not on when the
register was saved, the currently selected switcher sources will be
changed.
b.
If the
Auto Recall
button is off, the sources currently selected in the
Switcher source pane will be updated with the R-MEM values of
that register.
Note
A switcher source that is currently on-air with an On Air protection status
cannot be changed by an R-MEM recall. Either place the source off-air or
select a different protection status to change the switcher source selection.
Preview
When
Preview
mode is turned on, recalling a register will only display the
R-MEM settings stored in that register. No switcher sources will change.
This allows you to see what switcher sources will be affected by a register
recall, and what the router sources and destinations will be after the recall.
When
Preview
is turned off, the right pane returns to displaying the current
status, including any previously set enables.