beautypg.com

Run control button – Grass Valley Zodiak v.6.0 Mar 15 2006 User Manual

Page 133

background image

Zodiak — User Manual

133

2.5-M/E and 3-M/E Main Panel

Enter Button

The

Enter

button on the E-MEM subpanel is only used to complete a time

value entry on that keypad for an Auto Transition, Effect Dissolve, and
Sequence Delay.

Undo / • Button

The E-MEM

Undo/•

button is used to enter default values and decimal

points during data entry, and to undo the last action.

The two modes of the E-MEM

Undo/•

button, unshifted and shifted, is deter-

mined by the state of the

Bank

button. The exact

Undo/•

button behavior in

unshifted mode is determined by the operation that is performed next, and
in shifted mode is determined by what operation was performed last.

When unshifted (

Bank

is off)

the

Undo/•

button is used with Learn, Get, and

Put operations to represent the next available register (the default). The
unshifted

Undo/•

button is also used for Sequence and Effect Dissolve oper-

ations to represent the colon separator in time value entry.

When shifted (

Bank

is on)

and the last operation was an E-MEM register

operation (Learn, Recall, keyframe edit), pressing the

Undo/•

button will

undo the operation. If an operation has just been undone, pressing the
shifted

Undo/•

button will redo the operation. Thus, pressing

Bank

,

Undo/•

repeatedly allows toggling back and forth between the last two states of the
current effect. The

Undo/•

button must be used immediately after an undes-

ired operation, or it may be unable to undo it.

Run Control Button

The

Run

button in the upper left corner of the keypad will cause the current

effect to run. The button will light to indicate the run state. A effect run can
be stopped at any time by pressing the lit button (turning it off).