Delta DVP-ES2 User Manual
Page 75
2 . P r o g r a m m i n g C o n c e p ts
2 - 4 3
Special
D
Content
ES2
EX2
SS
2
SA
2
SX
2
OFF
Ø
ON
STOP
Ø
RUN
RUN
Ø
STOP
Attrib.
Latch
-ed
Default
D1187 Index register F3
○
○
○
○
0 - -
R/W
NO
0
D1188 Index register E4
○
○
○
○
0 - -
R/W
NO
0
D1189 Index register F4
○
○
○
○
0 - -
R/W
NO
0
D1190 Index register E5
○
○
○
○
0 - -
R/W
NO
0
D1191 Index register F5
○
○
○
○
0 - -
R/W
NO
0
D1192 Index register E6
○
○
○
○
0 - -
R/W
NO
0
D1193 Index register F6
○
○
○
○
0 - -
R/W
NO
0
D1194 Index register E7
○
○
○
○
0 - -
R/W
NO
0
D1195 Index register F7
○
○
○
○
0 - -
R/W
NO
0
D1220 Pulse output mode setting of CH0 (Y0, Y1)
○
○
○
○
0
- -
R/W
NO
0
D1221 Pulse output mode setting of CH1 (Y2, Y3)
○
○
○
○
0
- -
R/W
NO
0
D1232*
Number of output pulses for CH0 (Y0, Y1) ramp-
down stop when mark sensor receives signals.
(Low word).
○
○
○
○
0 0 --
R/W
NO
0
D1233*
Number of output pulses for CH0 (Y0, Y1) ramp-
down stop when mark sensor receives signals.
(High word).
○
○
○
○
0 0 --
R/W
NO
0
D1234*
Number of output pulses for CH1 (Y2, Y3) ramp-
down stop when mark sensor receives signals.
(Low word).
○
○
○
○
0 0 --
R/W
NO
0
D1235*
Number of output pulses for CH2 (Y2, Y3) ramp-
down stop when mark sensor receives signals.
(High word).
○
○
○
○
0 0 --
R/W
NO
0
D1240*
When interupt I400/I401/I100/I101 occurs,
D1240 stores the low word of high-speed counter.
○
○
○
○
0 0 - R
NO
0
D1241*
When interupt I400/I401/I100/I101 occurs,
D1241 stores the high Word of high-speed
counter.
○
○
○
○
0 0 - R
NO
0
D1242*
When interupt I500/I501/I300/I301 occurs,
D1242 stores the low Wordof high-speed counter.
○
○
○
○
0 0 - R
NO
0
D1243*
When interupt I500/I501/I300/I301 occurs, D1243
stores the high Word of high-speed counter.
○
○
○
○
0 0 - R
NO
0
D1244
Idle time (pulse number) setting of CH0 (Y0, Y1)
The function is disabled if set value≦0.
○
○
○
○
0 - -
R/W
NO
0
D1245
Idle time (pulse number) setting of CH1 (Y2, Y3)
The function is disabled if set value≦0.
○
○
○
○
0 - -
R/W
NO
0
D1249
Set value for COM1 (RS-232) data receiving time-
out (Unit: 1ms, min. 50ms, value smaller than
50ms will be regarded as 50ms) (only applicable
for MODRW/RS instruction) In RS instruction, no
time-out setting if “0” is specified.
○
○
○
○
0 - -
R/W
NO
0
D1250
COM1 (RS-232) communication error code (only
applicable for MODRW/RS instruction)
○
○
○
○
0 - -
R/W
NO
0
D1252
Set value for COM3 (RS-485) data receiving time-
out (Unit: 1ms, min. 50ms, value smaller than
50ms will be regarded as 50ms) (only applicable
for MODRW/RS instruction) In RS instruction, no
time-out setting if “0” is specified
○
╳
○
╳
50
- -
R/W
NO
50