D V P - E S 2 / S X 2 / S S 2 / S A2 / S X 2 / S E O p e r a t i o n M a n u a l – P r o g r a m m i n g

3 - 4 6 2

API Mnemonic

Operands

Function

206

ASDRW

ASDA servo drive
R/W

Controllers

ES2/EX2 SS2 SA2

SE

SX2

Bit Devices

Word devices

Program Steps

Type

OP

X Y M S K H

KnX

KnY KnM KnS T C D E F

S

1

*

*

*

S

2

*

*

*

S

*

ASDRW: 7 steps

PULSE 16-bit 32-bit

ES2/EX2 SS2

SA2

SE

SX2 ES2/EX2 SS2

SA2

SE

SX2 ES2/EX2 SS2

SA2

SE

SX2

Operands:

S

1

: Address of servo drive (K0~K254) S

2

: Function code S: Register for read/written data

Explanations:

1.

ASDRW communication instruction supports COM2 (RS-485) and COM3 (RS-485)

2.

S

1

: station number of servo drive. Range: K0~K254. K0 indicates broadcasting, i.e. PLC will

not receive feedback data.

3.

S

2

: function code. Please refer to the table below.

4.

S: Register for read/written data. Please refer to the table below for explanations.

5.

Explanations of function code:

Exclusively for ASDA of A-type, AB type, A+ type, B type

Code

Function

Parameter

Com. Addr.

Read/Write data (Settings)

K0(H0) Status monitor

P0-04 ~ P0-08 0004H ~

0008H

S+0 ~ S+4: Please refer to

explanations in ASDA manuals.

K1(H1) Block Data Read

Register

P0-09 ~ P0-16 0009H ~

0010H

S+0 ~ S+7: Please refer to

explanations in ASDA manuals.

B Type is not supported.

K2(H2) Block Data Write

Register

P0-09 ~ P0-16 0009H ~

0010H

S+0 ~ S+7: Please refer to

explanations in ASDA manuals.

B Type is not supported.

K3(H3) JOG Operation

P4-05

0405H

S: Range: 1~3000, 4999, 4998,

5000

K4(H4) Servo ON/OFF

P2-30

021EH

S: K1 = ON, Others = OFF

K5(H5) Speed Command

(3 sets)

P1-09 ~ P1-11 0109H ~

010BH

S+0 ~ S+2: Range:

-5000~+5000

K6(H6) Torque Command

(3 sets)

P1-12 ~ P1-14 010CH ~

010EH

S+0 ~ S+2: Range:

-300~+300