Delta DVP-ES2 User Manual
Page 352
D V P - E S 2 / E X 2 / S S 2 / S A2 / S X 2 / S E O p e r a t i o n M a n u a l - P r o g r a m m i n g
3-236
Program Example 2:
1.
M1161 = ON, 8-bit conversion.
2.
When X0 = ON, 6 bytes from low byte of D0 to low byte of D5 will be summed up, and the
checksum is stored in D100 while the parity bits are stored in D101.
X0
CCD
D0
D100
K6
M1000
M1161
0
0
0
0
0
1
1
1
1
1
0
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
1
D 10 0
D 10 1
Parity
D0 low byte
D1 low byte
D2 low byte
D3 low byte
D4 low byte
D5 low byte
D100
D101
(S)
Content of data
K100 = 0 1 1 0 0 1 0 0
K111 = 0 1 1 0 1 1 1 1
K120 = 0 1 1 1 1 0 0 0
K202 = 1 1 0 0 1 0 1 0
K123 = 0 1 1 1 1 0 1 1
K211 = 1 1 0 1 0 0 1 1
K867
0 0 0 1 0 0 0 1
The parity is 1 when there is a odd number of 1.
The parity is 0 when there is a even number of 1.
Total