beautypg.com

Delta DVP-ES2 User Manual

Page 300

background image

D V P - E S 2 / E X 2 / S S 2 / S A2 / S X 2 / S E O p e r a t i o n M a n u a l - P r o g r a m m i n g

3 - 1 8 4

0

1

2

3

4

5

6

7

8

9

D0

10

3

10

2

10

1

10

0

number key

BCD value 1-digit BCD code

BIN value

overflow

BCD value

160. As shown in the timing diagram below, four keys connected with X35, X33, X31 and X30 are

pressed in order. Therefore, the number 5,301 is generated and stored in D0. 9,999 is the

maximum value allowed for D0. If the entered number exceeds the available range, the

highest digit performs overflow.

161. When X35 is pressed, M15 remains ON until another key is pressed and the rule applies to

other inputs.

162. M20 = ON when any of the keys is pressed.

163. When X20 is OFF, the value in D0 remains unchanged but M10~M20 will be OFF.

X30

X31

X33

X35

1

2

3

4

1

2

3

4

M10

M11

M13

M15

M20

Key output
signal