D V P - E S 2 / E X 2 / S S 2 / S A2 / S X 2 / S E O p e r a t i o n M a n u a l - P r o g r a m m i n g

7.

C243 and C244 support count-up mode only and occupy the associate input points X1 and

X3 as reset (“R”) function. If users do not need to apply reset function, set ON the associated

special M relays (M1243 and M1244) to disable the reset function.

8.

“Dir” refers to direction control function. OFF indicates counting up; ON indicates counting

down.

9.

When X1, X3, X4 and X5 is applied for reset function and associated external interrupts are

disabled, users can define the reset function as Rising/Falling-edge triggered by special M

relays

Reset Function

X1

X3

X4

X5

R/F

M1271 M1273 M1274

M1275

10. When X1, X3, X4 and X5 is applied for reset function and external interrupts are applied, the

interrupt instructions have the priority in using the input points. In addition, PLC will move the

current data in the counters to the associated data registers below then reset the counters.

Special D

D1241, D1240

D1243, D1242

Counter C243

C246

C248

C252

C244

C250

C254

X3

(I300/I301)

X1

X5(I500/I501)

X4(I400/I401)

External Interrupt

(I100/I101)

Example:

M1000

DCNT

C243

K100

EI

FEND

I101

M1000

IRET

END

DMOV

D1240

D0

When C243 is counting and external interrupt is triggerred from X1(I101), counted value in C243

will be move to (D1241, D1240) immediately then C243 is reset. After this interrupt I101 executes.


1-phase 1 input high-speed counter:

Example:

LD

X20

C235

Y0

X22

C235

K5

DCNT

X21

C235

RST

X20

M1235

RST C235

LD X21

OUT M1235

LD X22

DCNT

C235 K5

LD C235

OUT Y0

2-36